24 research outputs found

    How wearable sensors have been utilised to evaluate frailty in older adults: a systematic review

    Get PDF
    Abstract Background Globally the population of older adults is increasing. It is estimated that by 2050 the number of adults over the age of 60 will represent over 21% of the world’s population. Frailty is a clinical condition associated with ageing resulting in an increase in adverse outcomes. It is considered the greatest challenge facing an ageing population affecting an estimated 16% of community-dwelling populations worldwide. Aim The aim of this systematic review is to explore how wearable sensors have been used to assess frailty in older adults. Method Electronic databases Medline, Science Direct, Scopus, and CINAHL were systematically searched March 2020 and November 2020. A search constraint of articles published in English, between January 2010 and November 2020 was applied. Papers included were primary observational studies involving; older adults aged > 60 years, used a wearable sensor to provide quantitative measurements of physical activity (PA) or mobility and a measure of frailty. Studies were excluded if they used non-wearable sensors for outcome measurement or outlined an algorithm or application development exclusively. The methodological quality of the selected studies was assessed using the Appraisal Tool for Cross-sectional Studies (AXIS). Results Twenty-nine studies examining the use of wearable sensors to assess and discriminate between stages of frailty in older adults were included. Thirteen different body-worn sensors were used in eight different body-locations. Participants were community-dwelling older adults. Studies were performed in home, laboratory or hospital settings. Postural transitions, number of steps, percentage of time in PA and intensity of PA together were the most frequently measured parameters followed closely by gait speed. All but one study demonstrated an association between PA and level of frailty. All reports of gait speed indicate correlation with frailty. Conclusions Wearable sensors have been successfully used to evaluate frailty in older adults. Further research is needed to identify a feasible, user-friendly device and body-location that can be used to identify signs of pre-frailty in community-dwelling older adults. This would facilitate early identification and targeted intervention to reduce the burden of frailty in an ageing population

    Measurement of Heart Rate Using the Withings ScanWatch Device during Free-living Activities : Validation Study

    Get PDF
    Funding Information: This research is part of the Eastern Corridor Medical Engineering (ECME) project, which has been funded by European Union’s INTERREG VA programme, managed by the Special EU Programmes Body (SEUPB).Peer reviewedPublisher PD

    Does Connected Health Technology Improve Health-Related Outcomes in Rural Cardiac Populations? Systematic Review Narrative Synthesis

    Get PDF
    Individuals living in rural areas are more likely to experience cardiovascular diseases (CVD) and have increased barriers to regular physical activity in comparison to those in urban areas. This systematic review aimed to understand the types and effects of home-based connected health technologies, used by individuals living in rural areas with CVD. The inclusion criteria included technology deployed at the participant’s home and could be an mHealth (smart device, fitness tracker or app) or telehealth intervention. Nine electronic databases were searched across the date range January 1990–June 2021. A total of 207 full texts were screened, of which five studies were included, consisting of 603 participants. Of the five studies, four used a telehealth intervention and one used a form of wearable technology. All interventions which used a form of telehealth found a reduction in overall healthcare utilisation, and one study found improvements in CVD risk factors. Acceptability of the technologies was mixed, in some studies barriers and challenges were cited. Based on the findings, there is great potential for implementing connected health technologies, but due to the low number of studies which met the inclusion criteria, further research is required within rural areas for those living with cardiovascular disease

    Measurement of Heart Rate Using the Polar OH1 and Fitbit Charge 3 Wearable Devices in Healthy Adults During Light, Moderate, Vigorous, and Sprint-Based Exercise: Validation Study

    Get PDF
    Background: Accurate, continuous heart rate measurements are important for health assessment, physical activity, and sporting performance, and the integration of heart rate measurements into wearable devices has extended its accessibility. Although the use of photoplethysmography technology is not new, the available data relating to the validity of measurement are limited, and the range of activities being performed is often restricted to one exercise domain and/or limited intensities.Objective: The primary objective of this study was to assess the validity of the Polar OH1 and Fitbit Charge 3 devices for measuring heart rate during rest, light, moderate, vigorous, and sprint-type exercise.Methods: A total of 20 healthy adults (9 female; height: mean 1.73 [SD 0.1] m; body mass: mean 71.6 [SD 11.0] kg; and age: mean 40 [SD 10] years) volunteered and provided written informed consent to participate in the study consisting of 2 trials. Trial 1 was split into 3 components: 15-minute sedentary activities, 10-minute cycling on a bicycle ergometer, and incremental exercise test to exhaustion on a motorized treadmill (18-42 minutes). Trial 2 was split into 2 components: 4 × 15-second maximal sprints on a cycle ergometer and 4 × 30- to 50-m sprints on a nonmotorized resistance treadmill. Data from the 3 devices were time-aligned, and the validity of Polar OH1 and Fitbit Charge 3 was assessed against Polar H10 (criterion device). Validity was evaluated using the Bland and Altman analysis, Pearson moment correlation coefficient, and mean absolute percentage error.Results: Overall, there was a very good correlation between the Polar OH1 and Polar H10 devices (r=0.95), with a mean bias of −1 beats·min-1 and limits of agreement of −20 to 19 beats·min-1. The Fitbit Charge 3 device underestimated heart rate by 7 beats·min-1 compared with Polar H10, with a limit of agreement of −46 to 33 beats·min-1 and poor correlation (r=0.8). The mean absolute percentage error for both devices was deemed acceptable

    Physical Activity Monitoring in Patients with Neurological Disorders: A Review of Novel Body-Worn Devices

    Get PDF
    Aim: The aim was to conduct a systematic review to examine the literature reporting the validityand reliability of wearable physical activity monitoring in individuals with neurologicaldisorders. Method: A systematic search of the literature was performed using a specific searchstrategy in PubMed and CINAHL. A search constraint of articles published in English, includinghuman participants, published between January 2008 and March 2017 was applied. Peerreviewedstudies which enrolled adult participants with any neurological disorder were included.For the studies which sought to explore the validity of activity monitors, the outcomesmeasured using the monitor were compared to a criterion measure of physical activity. Thestudies methodological quality was assessed using an adapted version of the Quality Assessmentof Diagnostic Accuracy Studies (QUADAS) framework. Data extracted from each studyincluded the following: characteristics of the study participants, study setting, devices used,study protocol/methods, outcomes measured, and the validity/reliability of measurementproduced. Results: Twenty-three studies examining the validity and reliability of 16 differentmonitors were included. The identified studies comprised participants with a range of differentdisorders of neurological origin. The available evidence suggests that biaxial or triaxialaccelerometer devices positioned around the ankle produce the most accurate step countmeasurements in patients with neurological disorders. The findings regarding the reliabilityand validity of activity counts and energy expenditure are largely inconclusive in this population.Discussion: Ankle-worn biaxial or triaxial accelerometer-type devices provide the mostaccurate measurement of physical activity. However, further work is required in this field before wearable activity monitoring can be more widely implemented clinically. Standardisedactivity monitoring protocols are required for implementing these devices in clinical trials andclinical practice, and consensus is required as to the reporting and interpretation of derivedvariablesScience Foundation Irelan

    The Use of Inertial Sensors for the Classification of Rehabilitation Exercises

    Get PDF
    2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Chicago, Illinois, United States of America, 26-30 August 2014The benefits of exercise in rehabilitation after orthopaedic surgery or following a musculoskeletal injury has been widely established. Within a hospital or clinical environment, adherence levels to rehabilitation exercise programs are high due to the supervision of the patient during the rehabilitation process. However, adherence levels drop significantly when patients are asked to perform the program at home. This paper describes the use of simple inertial sensors for the purpose of developing a biofeedback system to monitor adherence to rehabilitation programs. The results show that a single sensor can accurately distinguish between seven commonly prescribed rehabilitation exercises with accuracies between 93% and 95%. Results also show that the use of multiple sensor units does not significantly improve results therefore suggesting that a single sensor unit can be used as an input to an exercise biofeedback system

    Rehabilitation exercise assessment using inertial sensors: a cross-sectional analytical study

    Get PDF
    Background: Accurate assessments of adherence and exercise performance are required in order to ensure that patients adhere to and perform their rehabilitation exercises correctly within the home environment. Inertial sensors have previously been advocated as a means of achieving these requirements, by using them as an input to an exercise biofeedback system. This research sought to investigate whether inertial sensors, and in particular a single sensor, can accurately classify exercise performance in patients performing lower limb exercises for rehabilitation purposes. Methods:Fifty-eight participants (19 male, 39 female, age: 53.9 +/- 8.5 years, height: 1.69 +/- 0.08 m, weight: 74.3 +/- 13.0 kg) performed ten repetitions of seven lower limb exercises (hip abduction, hip flexion, hip extension, knee extension, heel slide, straight leg raise, and inner range quadriceps). Three inertial sensor units, secured to the thigh, shin and foot of the leg being exercised, were used to acquire data during each exercise. Machine learning classification methods were applied to quantify the acquired data. Results:The classification methods achieved relatively high accuracy at distinguishing between correct and incorrect performance of an exercise using three, two, or one sensor while moderate efficacy scores were also achieved by the classifier when attempting to classify the particular error in exercise performance. Results also illustrated that a reduction in the number of inertial sensor units employed has little effect on the overall efficacy results. Conclusion:The results revealed that it is possible to classify lower limb exercise performance using inertial sensors with satisfactory levels of accuracy and reducing the number of sensors employed does not reduce the accuracy of the methodScience Foundation Irelan
    corecore